OPERATIONAL QUALIFICATION FOR VIBRO SIFTER [PICTORIAL]

Operational Qualification (OQ) for Vibro Sifter [PICTORIAL]

Check that the Vibro sifter operates correctly without product under defined operating ranges.

Typical OQ tests & checks:

  1. Startup / No-Load Trial
    • Verify smooth start and stop.
    • No abnormal noise, vibration, or smell.
    • Direction of vibration as per design.
  2. Safety Checks
    • Emergency stop – machine must stop immediately.
    • Power failure simulation – machine stops; behaviour on power resumption recorded (manual restart preferred).
    • Ensure control panel is labeled and safe.
    • Ensure interlocking of Castor Wheels to avoid unwanted movement of Vibro Sifter during processing.

Operational Qualification Acceptance:

  • All controls & safety systems function as designed.
  • No abnormal vibration/noise; no product bypass risk seen.