“Water” forms the most important ingredient in the pharmaceutical manufacturing process and also finds a major use in cleaning of equipment before and after processing. However due to its tendency to give way to microbiological proliferation during storage and distribution, it becomes a “critical” ingredient as well. Thus emphasis is given on water system maintenance and further checks are required during storage, distribution and use. The Water System Qualification and SOP in Pharma provides a detailed view into the technical aspects, testing, validation and reporting pattern for “water”. It further reinforces the company’s commitment to maintain GMP. The plant is to provide the total amount of Purified water & Water for Injection for pharmaceutical use, i.e. so-called Purified water & Water for Injection quality as per WHO specifications which must quality pH, Calcium & Magnesium, Heavy metals, Chloride, Nitrate, Sulphate, TOC, Conductivity, Microbial counts, Bacterial Endotoxin Test etc. by means of new Generation Plant. The plant must comply with the requirements of the pharmacopoeia and the cGMP regulations as well as with WHO inspection regulations for plants producing Purified water & water for Injection. For the same the water system qualification and SOP in Pharma plays important role.
QUALIFICATION
- URS for Purified Water System
- IQ for Process Water
- IQ for Purified Water Generation System
- IQ for Purified Water Distribution System
- OQ for Purified Water Generation System
- OQ for Process Water Generation & Distribution System
- OQ Protocol Cum Report for Purified Water Pre-treatment System
- OQ Protocol Cum Report for Purified Water Generation System
- Operational Qualification Protocol for Purified Water Storage & Distribution System
- OQ Protocol Cum Report for Purified Water Distribution System
- PQ for Process Water
- PQ for Purified Water Generation System
- PQ for Purified Water Storage & Distribution System
- Qualification of TOC Analyser
- Installation Qualification for Purified Water Generation System
- Operational Qualification Protocol for Purified Water Generation System
- Installation Qualification Protocol for Purified Water Storage & Distribution System
- Operational Qualification Protocol for Purified Water Storage & Distribution System
- Operational Qualification for PLC System of Soft Water Distribution System
- Performance Qualification for Generation & Distribution System (Phase – I)
- Performance Qualification for Generation & Distribution System (Phase – II)
- Performance Qualification for Generation & Distribution System (Phase – III)
- Requalification Protocol for Purified Water Storage & Distribution System
- Hydro Test Qualification Protocol for Purified Water Tank
- Qualification for Spray Ball Coverage Test in WFI System
- Drain Time Validation Protocol
- Drain Time Validation Report
STANDARD OPERATING PROCEDURES OF WATER SYSTEM
- SOP for Qualification of Water System
- SOP for Specifications of Mixed Bed Unit
- SOP for Sanitization of Mixed Bed Unit
- SOP for Sanitization of Multi Column Distillation Plant
- SOP for Sanitization of Purified and Distilled Water Loop
- SOP for Sanitization of RO Water Plant
- SOP for Specifications of Filters for Purified Water and WFI
- SOP for Specifications of UV Lamps
- SOP for Calibration of pH Meter
- SOP for Chemical Preparation in Utility Safety Measures
- SOP for Chlorination Dosing in Raw Water
- SOP for Cleaning of Mixed Bed Unit Resins
- SOP for Cleaning of Reverse Osmosis (RO) Plant Membrane
- SOP for De-Scaling of Multi Column Distillation Plant
- SOP for Operation of Mixed Bed
- SOP for Operation of Multi Column Distillation Plant
- SOP for Operation of Multi Grade Sand Filter (MGF)
- SOP for Operation of Reverse Osmosis Plant
- SOP for Spray Ball Coverage Verification
- SOP for Passivation of Pure Steam Generation and Distribution System
- SOP for Operation of PLC based Water System
- SOP for Passivation of Equipment & Water System
- SOP for UV Intensity measurement and Calculation of Dose
- SOP for Testing of Water Hardness
- SOP for Spray Ball Coverage Verification
- SOP for Sanitization of UF Membrane
- SOP for Sanitization of RO Membrane
- SOP for Sanitization of EDI System
- SOP for RO Membrane loading & replacements
- SOP for Replacement of Sand in Multi Grade Filter
- SOP for Replacement of Resins of Mixed Bed Unit
- SOP for replacement of Resin at Softener
- SOP for Replacement of Cartridge Filter and Vent Filter
- SOP for Regeneration of Softener
- SOP for Regeneration of Mixed Bed Unit
- SOP for Operation of Purified Water Circulation Loop
- SOP for Operation of MCDP
- SOP for Operation of Pretreatment Plant
- SOP for Sanitization of WFI Storage and Distribution System
- SOP for Replacement of Media in Multi Grade Filter
- SOP for FDV Challenge Test
- SOP for Circulation Loop Qualification for Purified Water System
- SOP for Sanitization of Purified Water Storage and Distribution System
- SOP for Passivation of Purified Water Storage and Distribution System
- SOP for Procedure for Operation and Replacement of Ultra Violet Lamps
- SOP for Filter Integrity Testing and Replacement of Vent filters
- SOP for Sanitization of Purified Water Generation System
- SOP for Solution Preparation and Dosing in Purified Water Generation System
- SOP for Water Sampling for Chemical Analysis and Trend Preparation
- SOP for Microbiological analysis of Raw water, Process Potable water & Purified water
- SOP for Microbiological Analysis of Water for Injection and Pure Steam
- SOP for Sampling of Raw Water, Potable water, Purified Water and Pure Steam for Microbiological Analysis
- SOP for Cleaning and Sanitization of High Density Polyethylene Soft Water Storage Tank
- SOP for Operation of Purified Water Circulation Loop
- SOP for Operation of MCDP
- SOP for Cleaning & Sanitization of Purified Water System
- SOP for Sampling procedure of Purified Water and Raw Water
- SOP for Handling of Wash Water
- SOP for Sanitization of RO EDI System
- SOP for Sterilization of WFI Water Tank Loop Line
- SOP for Passivation of Equipment & Water System
- SOP for Handling of Out of Limit Results in Environmental Monitoring and Water Analysis
- SOP for Operation and Maintenance of Water Purification System
- SOP for Procedure for Analysis of Water
- SOP for Sampling and Testing of Potable Water
- SOP for Sampling and Testing of Purified Water
- SOP for Sampling and Testing of Source Water
- SOP for Water Sampling Procedure
- SOP for Recording of Water Consumption Data
- SOP for Analytical Data of Water Analysis
- SOP for Sampling procedure for water samples
- SOP for Analysis of Water and Pure Steam samples
- SOP for Analysis of Water
- SOP for Identification & Characterization of Environmental and Water isolates
- SOP for Microbial Limit Test of Water, Non-sterile Product & Material
- SOP for Procedure for the detection of Bacterial Endotoxin in water for Injection and Pure Steam Condensate by Gel Clot method
- SOP for Chlorination Dosing in Raw Water
- SOP for Operation of Ultra Pure Water System
- SOP for Preventive Maintenance of Distilled Water Plant (WFI-Plant)
- SOP for Procedure for De-Chlorination in Potable Water
- SOP for Procedure for Operation of Raw Water Pumps
- SOP for Procedure for Wash Water Sample Analysis
- SOP for Sanitization of Purified and Distilled Water Loop
- SOP for Sanitization of RO Water Plant
- SOP for Testing of Water Hardness
- SOP for Recording of Water Consumption Data
- SOP for Operation of Purified Water System
- SOP for Procedure for Integrity Testing & Replacement of Vent Filter of Water System